Revision notesFull · Section 2: Technical aspects
Transformers, sampling and aliasing
Mutual inductance, the voltage, current and impedance ratios of a transformer, core materials and losses, and how sampling, aliasing and the Fourier transform work.
Key points
Mutual inductanceA changing current in one coil induces a voltage in another sharing its field.
Voltage and currentVs = Vp × Ns ÷ Np; Ip = Is × Ns ÷ Np. Power in ≈ power out.
ImpedanceZp = Zs × (Np ÷ Ns)². A 4:1 impedance ratio needs 2:1 turns.
CoresLaminated iron for mains and audio; ferrite and powdered iron for RF. Core losses heat the core; more power needs a bigger core.
SamplingSample above twice the highest frequency. Above half the rate (Nyquist), signals alias; an anti-aliasing low pass filter prevents it.
Fourier transformConverts time-domain samples to amplitudes and frequencies (the frequency domain).
Covered in the full lesson
- Voltage
- Current
- Impedance
- Cores
- Nyquist
- Fourier transform
Quick check
An exam-style question on this lesson. Open it to see the answer and why.
A transformer has 500 primary turns and 50 secondary turns, with 230 V in. What is the secondary voltage?
- 23 V
- 2300 V
- 46 V
- 11.5 V
Answer: A. Vs = 230 × 50 ÷ 500 = 23 V.
Can you work it out?
230 V feeds a 1000-turn primary; the secondary has 60 turns. Find the secondary voltage.
The full lesson walks through the working step by step, with 4 worked examples in all.
The full lesson adds more
In the Full course this lesson has a short video, drills, flashcards and a printable revision sheet, and the course ends with 5 full mock exams.
Previous: Resonance, Q, dynamic resistance and crystals · Next: Semiconductors: Zener diodes, biasing, amplifier types and oscillators