Revision notesIntermediate · Section 4: Feeders and antennas

Feeders, baluns, SWR and matching

Balanced and coaxial feeders, characteristic impedance, feeder loss in decibels, choke baluns, standing waves, and what an antenna matching unit can and can't do.

Key points

Balanced feederEqual, opposite currents; fields cancel unless nearby objects upset the balance. Lower loss than coax; 75–600 Ω.
Coaxial cableField stays inside when correctly connected and terminated. 50 Ω for amateur use; 75 Ω for TV and satellite.
Characteristic impedanceSet by conductor diameter and spacing; the ratio of RMS V to RMS I in a correctly terminated feeder.
Feeder loss3 dB: half the power arrives. 10 dB: a tenth. Losses in dB add.
SWRReflected power forms standing waves; both waves suffer feeder loss; the input impedance changes.
AMUChanges the impedance the transmitter sees; doesn't tune the antenna or feeder; at the rig it doesn't change the feeder SWR.
Choke balunCoiled coax or ferrite rings; stops current on the outside of the screen.

Covered in the full lesson

  • 3 dB
  • 6 dB
  • 10 dB
  • 13 dB
  • 20 dB

Quick check

An exam-style question on this lesson. Open it to see the answer and why.

A transmitter delivers 100 W into a feeder with 3 dB loss. How much power reaches the antenna?
  1. 50 W
  2. 97 W
  3. 33 W
  4. 10 W
Answer: A. 3 dB is a halving of power.

Can you work it out?

A 100 W transmitter feeds a cable with 6 dB loss. Find the power at the antenna.

The full lesson walks through the working step by step, with 2 worked examples in all.