Revision notesFull · Section 9: Measurements and construction

Measuring power and frequency, decibels and temperature effects

Frequency measurement accuracy near band edges, crystal calibrators, counters and standard frequencies, measuring RF power and PEP, decibel calculations, and temperature effects on components.

Key points

Frequency uncertaintyInstrument tolerance, calibration and drift. Near a band edge allow for uncertainty plus the transmitted bandwidth.
ReferencesCrystal calibrator (as good as its crystal), digital counter (as good as its timebase; needs a steady signal), standard frequency transmissions (propagation limits).
RF powerP = Vrms² ÷ R across a dummy load. Use a steady audio tone for AM and SSB.
PEPPeak-reading power meter, or scope and dummy load: PEP = (Vpeak ÷ √2)² ÷ R.
DecibelsPower: 10 log (P2 ÷ P1); dBW (1 W), dBm (1 mW). Voltage: 20 log (V2 ÷ V1); dBV (1 V).
TemperatureNegative coefficient: value falls as it warms; positive: rises. Remedies: NP0 parts, cancelling coefficients, keep away from heat, warm up.

Covered in the full lesson

  • Steady RF power
  • PEP
  • Power in dB
  • Voltage in dB
  • 100 W
  • Band edge

Quick check

An exam-style question on this lesson. Open it to see the answer and why.

What power is dissipated when 70.7 V RMS is across a 50 Ω dummy load?
  1. 100 W
  2. 141 W
  3. 3535 W
  4. 50 W
Answer: A. P = 70.7² ÷ 50 ≈ 100 W.

Can you work it out?

Find the power when 70.7 V RMS is across 50 Ω.

The full lesson walks through the working step by step, with 4 worked examples in all.