Revision notesFull · Section 6: Electromagnetic compatibility
How interference happens: blocking, cross-modulation, rectification and images
Why installation affects immunity, your EMC responsibilities, non-compliant equipment, blocking and cross-modulation, passive intermodulation, rectification, masthead amplifiers, IF and image interference.
Key points
InstallationImmunity depends on installation; poor installation can compromise a good product.
ResponsibilityAmateurs needn't demonstrate EMC compliance of their equipment but must meet the licence's interference requirements.
Non-compliant equipmentSome imported or home-built devices and toys; cordless and mobile phones and IT equipment can cause short-range interference.
Blocking vs cross-modulationBlocking: strong steady signal (e.g. FM) swamps or mutes. Cross-modulation: strong varying signal (AM/SSB) adds its modulation.
Other mechanismsPassive intermodulation from corrosion; audio pick-up via speaker leads; rectification at any junction; overloaded wideband masthead amplifiers.
IF and imageMW 526–1606 kHz; FM 87.5–108 MHz; DAB 174–230 MHz; TV 470–694 MHz; radio IFs 455–500 kHz and 10.7 MHz; digital TV IFs 4–39 MHz.
Covered in the full lesson
- Medium wave
- FM broadcast
- DAB
- TV
- Radio IFs
- Digital TV IFs
Quick check
An exam-style question on this lesson. Open it to see the answer and why.
A strong steady FM signal mutes a nearby receiver's wanted signal. What is this?
- Blocking
- Cross-modulation
- Image interference
- Passive intermodulation
Answer: A. Also called desensitisation.
The full lesson adds more