Revision notesFull · Section 6: Electromagnetic compatibility

How interference happens: blocking, cross-modulation, rectification and images

Why installation affects immunity, your EMC responsibilities, non-compliant equipment, blocking and cross-modulation, passive intermodulation, rectification, masthead amplifiers, IF and image interference.

Key points

InstallationImmunity depends on installation; poor installation can compromise a good product.
ResponsibilityAmateurs needn't demonstrate EMC compliance of their equipment but must meet the licence's interference requirements.
Non-compliant equipmentSome imported or home-built devices and toys; cordless and mobile phones and IT equipment can cause short-range interference.
Blocking vs cross-modulationBlocking: strong steady signal (e.g. FM) swamps or mutes. Cross-modulation: strong varying signal (AM/SSB) adds its modulation.
Other mechanismsPassive intermodulation from corrosion; audio pick-up via speaker leads; rectification at any junction; overloaded wideband masthead amplifiers.
IF and imageMW 526–1606 kHz; FM 87.5–108 MHz; DAB 174–230 MHz; TV 470–694 MHz; radio IFs 455–500 kHz and 10.7 MHz; digital TV IFs 4–39 MHz.

Covered in the full lesson

  • Medium wave
  • FM broadcast
  • DAB
  • TV
  • Radio IFs
  • Digital TV IFs

Quick check

An exam-style question on this lesson. Open it to see the answer and why.

A strong steady FM signal mutes a nearby receiver's wanted signal. What is this?
  1. Blocking
  2. Cross-modulation
  3. Image interference
  4. Passive intermodulation
Answer: A. Also called desensitisation.

The full lesson adds more

In the Full course this lesson has a short video, drills, flashcards and a printable revision sheet, and the course ends with 5 full mock exams.

See the course

Next: Curing interference: filters, field strength, bonding, vehicles and complaints